Specification
Product Name | Vortex Tube - Medium | ||
Supply | Compressed Air | ||
Air Pressure | 4-9Bar | ||
Kits | Magnetic Base, Ball Valve, Push-in Fitting, Coolant Tube | ||
Magnetic Base Size | DN80 | ||
Inlet Port | 1/4"BSPT | ||
Hot Air Outlet Port | 1/4"BSPT |
Model
SMALL VORTEX TUBE
SMALL VORTEX TUBE
WITH COLD END OUTLET CONNECTOR D8
Order number | Inlet pressure | Air consumption | Refrigerating capacity | noise | ||||
Psi | Bar | SCFM | SLPM | Btu/H | Kcal/H | Watts | dBA | |
XR-W02K | 100 | 6.9 | 2 | 56 | 135 | 34 | 45 | 68 |
XR-W04K | 100 | 6.9 | 4 | 113 | 175 | 70 | 91 | 70 |
XR-W08K | 100 | 6.9 | 8 | 227 | 550 | 140 | 182 | 72 |
XR-W09K | 100 | 6.9 | 9 | 252 | 630 | 160 | 208 | 75 |
WITH MAGNETIC BASE AND UNIVERSAL TUBE
Order number | Inlet pressure | Air consumption | Refrigerating capacity | noise | ||||
Psi | Bar | SCFM | SLPM | Btu/H | Kcal/H | Watts | dBA | |
XR-W02BT | 100 | 6.9 | 2 | 56 | 135 | 34 | 45 | 68 |
XR-W04BT | 100 | 6.9 | 4 | 113 | 175 | 70 | 91 | 70 |
XR-W08BT | 100 | 6.9 | 8 | 227 | 550 | 140 | 182 | 72 |
XR-W09BT | 100 | 6.9 | 9 | 252 | 630 | 160 | 208 | 75 |
MEDIUM VORTEX TUBE
WITH COLD END OUTLET CONNECTION
Order number | Inlet pressure | Air consumption | Refrigerating capacity | noise | ||||
Psi | Bar | SCFM | SLPM | Btu/H | Kcal/H | Watts | dBA | |
XR-W10K | 100 | 6.9 | 10 | 283 | 650 | 164 | 213 | 75 |
XR-W15K | 100 | 6.9 | 15 | 420 | 1000 | 252 | 323 | 80 |
XR-W25K | 100 | 6.9 | 25 | 680 | 1700 | 428 | 528 | 82 |
XR-W30K | 100 | 6.9 | 30 | 820 | 2000 | 504 | 821 | 84 |
XR-W40K | 100 | 6.9 | 40 | 1100 | 2800 | 706 | 1180 | 88 |
WITH MAGNETIC SEAT AND UNIVERSAL TUBE
Order number | Inlet pressure | Air consumption | Refrigerating capacity | noise | ||||
Psi | Bar | SCFM | SLPM | Btu/H | Kcal/H | Watts | dBA | |
XR-W10BT | 100 | 6.9 | 10 | 283 | 650 | 164 | 213 | 75 |
XR-W15BT | 100 | 6.9 | 15 | 420 | 1000 | 252 | 323 | 80 |
XR-W25BT | 100 | 6.9 | 25 | 680 | 1700 | 428 | 528 | 82 |
XR-W30BT | 100 | 6.9 | 30 | 820 | 2000 | 504 | 821 | 84 |
XR-W40BT | 100 | 6.9 | 40 | 1100 | 2800 | 706 | 1180 | 88 |
WITH COLD END SILENCER
Order number | Inlet pressure | Air consumption | Refrigerating capacity | noise | ||||
Psi | Bar | SCFM | SLPM | Btu/H | Kcal/H | Watts | dBA | |
XR-W10VK | 100 | 6.9 | 10 | 283 | 650 | 164 | 213 | 65 |
XR-W15VK | 100 | 6.9 | 15 | 420 | 1000 | 252 | 323 | 70 |
XR-W25VK | 100 | 6.9 | 25 | 680 | 1700 | 428 | 528 | 73 |
XR-W30VK | 100 | 6.9 | 30 | 820 | 2000 | 504 | 821 | 74 |
XR-W40VK | 100 | 6.9 | 40 | 1100 | 2800 | 706 | 1180 | 78 |
FLANGE SEAT MOUNTING
Order number | Inlet pressure | Air consumption | Refrigerating capacity | noise | ||||
Psi | Bar | SCFM | SLPM | Btu/H | Kcal/H | Watts | dBA | |
XR-W10FT | 100 | 6.9 | 10 | 283 | 650 | 164 | 213 | 75 |
XR-W15FT | 100 | 6.9 | 15 | 420 | 1000 | 252 | 323 | 80 |
XR-W25FT | 100 | 6.9 | 25 | 680 | 1700 | 428 | 528 | 82 |
XR-W30FT | 100 | 6.9 | 30 | 820 | 2000 | 504 | 821 | 84 |
XR-W40FT | 100 | 6.9 | 40 | 1100 | 2800 | 706 | 1180 | 88 |
LARGE VORTEX TUBE
WITH COLD END OUTLET CONNECTION
Order number | Inlet pressure | Air consumption | Refrigerating capacity | noise | ||||
Psi | Bar | SCFM | SLPM | Btu/H | Kcal/H | Watts | dBA | |
XR-W50 | 100 | 6.9 | 50 | 1416 | 3400 | 857 | 1285 | 90 |
XR-W75 | 100 | 6.9 | 75 | 2124 | 5100 | 1285 | 1927 | 94 |
XR-W100 | 100 | 6.9 | 100 | 2832 | 6800 | 1700 | 2550 | 95 |
XR-W150 | 100 | 6.9 | 150 | 4248 | 10200 | 2570 | 3855 | 96 |
ALUMINUM ALLOY VORTEX TUBE
ALL ALUMINUM ALLOY VORTEX TUBE
Order number | Inlet pressure | Air consumption | Refrigerating capacity | noise | ||||
Psi | Bar | SCFM | SLPM | Btu/H | Kcal/H | Watts | dBA | |
XR-W10BTAL | 100 | 6.9 | 10 | 260 | 650 | 164 | 180 | 75 |
XR-W15BTAL | 100 | 6.9 | 15 | 420 | 1000 | 252 | 323 | 80 |
XR-W25BTAL | 100 | 6.9 | 25 | 680 | 1700 | 428 | 528 | 82 |
XR-W30BTAL | 100 | 6.9 | 30 | 820 | 2000 | 504 | 821 | 84 |
XR-W40BTAL | 100 | 6.9 | 40 | 1100 | 2800 | 706 | 1180 | 88 |
Installation
2. Cold Air Inlet is turned to the items cooled.
3. Compressed air supply is connected to the inlet with a pressure of 4-9 Bar.
4. Use ball valve to control on and off of air supply.
5. Firstly, unscrew 1/8"BSPT seal screw on the end of gun, and then use a slot screwdriver to rotate the position with clockwise to increase cooling capacity, and vice versa.
Note: Don't screw too tight ! Otherwise, it cannot achieve cooling effect.
1. Widely used in milling, drilling, turning and other metalworking operations
2. Machining of plastics, composites, wood and other materials
3. Surface grinding, drill and tool sharpening
4. CNC routers, blades and band saws
5. Spot cooling of parts, molds and assemblies
6. Industrial sewing and textiles
7. Setting hot melts and adhesives
If Cold Air Gun dose not perform properly, check for these common problems:
1. Inlet Pressure.
Low inlet pressure supply will cause poor performance.
(standard pressure of the cooling gun is 6.9 Bar)
Usually compressed air does not use only one tool or device, so the pressure and flow rate of the terminal will be reduced.
2. The inner diameter of the compressed air pipe is not large enough, resulting in low pressure supply.
3. The internal diameters of various fittings of compressed air are smaller than the internal diameter of the pipes, so the pressure will lost in many places and the flow rate will be reduced.
4. Pipes or fittings are leaky
5. Inlet Temperature.
A Cold Gun provides a temperature drop from supply air temperature. In some cases, the supply air is warmer than ambient air due to compressed air lines running across ceilings, near furnaces, direct sun, etc. In this case, the cold air may be warmer than anticipated and adequate refrigeration may not be available for the application.
6. Back Pressure.
The performance of a Cold Gun deteriorates with back pressure on the cold end exhaust. Use only the flexible segmented hose included with the Cold Gun System.
7. No Cold Flow.
If the filter is not drained regularly, water may overflow into the Cold Gun and cause internal freezing. This can reduce or even stop cold air flow. Drain the filter often, or crack open for a small continuous air bleed. If internal freezing occurs, any one of the following will correct the problem:
Solutions
1.Please increase the supply of compressed air.
2.For the compressed air input hose, please use 10-12 mm. If you use a suitable fittings, it will increase the flow of compressed air.
3.Please check whether the pipe system is leaking.
4.Blow air (use an air gun) into the cold muffler with the Cold Gun off.
5. Turn the Cold Gun off for a few minutes.
6. Put a dryer on the compressed air supply.
Note: The high temperature of the hot air end is normal, but please take care to prevent accidents.
When the hot air has not been discharged, part of the heat has been transferred to the vortex tube, so the temperature is not high after being discharged from the gun body, and it does not harm to the human body.